Cue App Settings via OTA
OTA settings allow you to configure the interactive mode settings wirelessly.
Steps for OTA Configuration
Perform OTA configuration using the following steps.
1. Launch the TWELITE STAGE APP
Install the TWELITE STAGE SDK on your PC, then launch TWELITE_Stage
in the MWSTAGE folder.
2. Write the OTA configuration app to the MONOSTICK
Open 2: Rewrite App > 1: Select from BIN, and select App_CUE_OTA_...
.
3. Enter configuration values in interactive mode
Select 3: Interactive Mode, then edit and save the values.
4. Execute the OTA configuration
Place the TWELITE CUE within about 20cm of the MONOSTICK. Turn on the main unit’s power or bring a magnet close to the magnetic sensor more than 5 times to confirm that the TWELITE CUE’s LED is blinking.
5. Confirm the output from the MONOSTICK
Check for the following output messages.
If no output is displayed, see here.
6. Rewrite the app back to the MONOSTICK
Open 2: Rewrite App > 1: Select from BIN, and select App_Wings_MONOSTICK_...
.
OTA Failure Cases
Distance is too far
The following message indicates that the distance is too far.
OTA FAILURE
OTA request TS=20515[ms]
LQI:63 (RF strength, >= 100)
SID:810BA765
TWELITE CUE:v1.1.1
Protocol Version:0x11
--— LQI is small. Please make TWELITE CUE closer. —--
In this case, bring the MONOSTICK and TWELITE CUE closer together.
Wrong target
The following message indicates that the TWELITE CUE firmware is different or that the wrong TWELITE CUE is being approached.
OTA FAILURE
OTA request TS=20515[ms]
LQI:180 (RF strength, >= 100)
SID:810BA765
TWELITE CUE:v1.1.1
Protocol Version:0x13
--— Different protocol version. Please update TWELITE CUE. —--
In this case, check that you are not approaching the wrong TWELITE CUE.
Also, if you have rewritten the TWELITE CUE firmware, please use TWELITE R2/R3 to rewrite it back to App_CUE
.